Hospital HVAC & Laminar Airflow Solutions
Advanced cleanroom systems for OTs, ICUs, and critical care areas with HEPA filtration
Complete HVAC & Airflow Solutions
We provide hospital HVAC solutions tailored for critical areas. This includes design and installation of air handling units, split ACs, and HEPA-filtered laminar flow systems to maintain clean, temperature-controlled environments.
Our laminar airflow solutions ensure unidirectional filtered air in OTs and labs. We offer ongoing maintenance – from air filter integrity tests and HEPA filter checks to balancing temperature/humidity and airflow distribution.
Regular HVAC servicing and laminar flow cleaning guarantee air quality and sterility in sensitive zones. Our systems comply with NABH, ISO, and international healthcare standards for infection control.
Why Choose Our HVAC Solutions
HEPA Filtration
99.97-99.995% particle removal efficiency for Class 100/1000 cleanroom standards in critical areas.
Precise Climate Control
Accurate temperature (20-24°C) and humidity (40-60%) control with ±2°C precision for patient comfort.
Infection Control
Laminar airflow systems with positive pressure gradients to prevent cross-contamination.
Our HVAC Services
Design & Installation
Complete HVAC system design and installation for hospitals, clinics, and healthcare facilities.
- • Air Handling Units (AHU)
- • Split AC Systems
- • Ductwork Design
- • Control Systems
Laminar Airflow Systems
Cleanroom laminar airflow solutions for operation theatres, ICUs, and isolation rooms.
- • HEPA Filter Integration
- • Unidirectional Airflow
- • Pressure Control
- • Air Change Rate Management
Maintenance Services
Comprehensive HVAC maintenance and servicing for optimal performance and efficiency.
- • Filter Integrity Testing
- • System Calibration
- • Preventive Maintenance
- • Emergency Repairs
Our HVAC Installations
HVAC System Components
Air Handling Units
Custom AHUs with multiple filtration stages for hospital environments.
HEPA Filters
H13/H14 grade HEPA filters with 99.97-99.995% efficiency for critical areas.
Laminar Flow Ceilings
Perforated ceilings for unidirectional airflow in OTs and cleanrooms.
Climate Control
Precise temperature and humidity control systems with digital monitoring.
Control Systems
BMS integration with touch screen controls and remote monitoring.
Monitoring Systems
Pressure, temperature, humidity, and filter status monitoring with alarms.
Laminar Airflow Process
Hospital Air Filtration Process
Air Intake & Pre-Filtration
Outside air is drawn through pre-filters (G4) removing large particles (>5μm) and dust before entering the system.
Primary Filtration
Air passes through bag filters (F7/F9) removing particles down to 1μm with 85-95% efficiency.
Temperature Control
Air is cooled/heated to 20-24°C and humidity adjusted to 40-60% RH for optimal comfort.
HEPA Filtration
Final HEPA filtration (H13/H14) removes 99.97-99.995% of particles ≥0.3μm.
Laminar Distribution
Clean air is distributed through laminar flow ceilings creating unidirectional airflow at 0.25-0.35 m/s.
Maintenance Services
Preventive Maintenance Schedule
Visual Inspection
Check filters, belts, motors, and overall system operation.
Filter Inspection
Check pre-filters and bag filters for clogging and replacement needs.
Comprehensive Service
Full system cleaning, belt tension check, motor lubrication.
HEPA Filter Testing
DOP testing for HEPA filter integrity and efficiency verification.
Complete System Audit
Full system calibration, airflow balancing, and performance certification.
Maintenance Services Include
- Air filter integrity tests and HEPA filter checks
- Temperature and humidity balancing
- Airflow distribution optimization
- System calibration and performance testing
- Emergency repair services 24/7
Benefits of Regular Maintenance
- Improved air quality and infection control
- Energy efficiency and reduced operating costs
- Extended system lifespan and reliability
- Compliance with healthcare standards and regulations
- Preventive maintenance reduces emergency repair costs
Hospital Applications
Operation Theatres
Class 100/1000 laminar airflow systems with HEPA filtration for surgical sterility and infection control.
ICUs & CCUs
Specialized HVAC for critical care with precise temperature control and air quality monitoring.
Laboratories
Cleanroom environments for pathology, microbiology, and pharmaceutical labs.
Isolation Rooms
Negative pressure isolation rooms for infectious disease control and patient isolation.
NICU & PICU
Specialized climate control for neonatal and pediatric intensive care units.
Pharmacy
Cleanroom HVAC for IV preparation, sterile compounding, and pharmaceutical storage.
Standards & Compliance
Quality Assurance Parameters
Air Quality Standards
- • Particle count: ≤ 3,520 particles/m³ (Class 1000)
- • Air changes: 20-25 ACH for critical areas
- • Pressure differential: +15 to +25 Pa
- • Microbial count: ≤ 10 CFU/m³
Testing & Validation
- • DOP testing for HEPA filter integrity
- • Airflow velocity and uniformity testing
- • Pressure differential validation
- • Particle count verification
Need Professional HVAC Solutions?
Get expert HVAC design, installation, and maintenance services for your healthcare facility.